4.11.2.6
Run Field Replaceable Unit/Sensor Data Record (FRU/SDR)
Update
Use this menu item to re-inventory the FRUs and Sensor Data Records (SDR) on the
Sun Fire V60x and Sun Fire V65x servers. The FRU/SDR code resides both on the
Sun Fire V60x and Sun Fire V65x servers Diagnostics CD and on the Service
Partition in the
Typically, the product and chassis serial numbers are changed only by field service
personnel when hardware is changed. The asset tag number is intended for use by
customers for their internal tracking system. For example, the asset tag might be
updated after a firmware or software update.
4.11.2.7

Run BIOS Update (reboot required)

Use this menu item to update the BIOS Boot block in the event that the boot block
becomes corrupted. Use this menu item to also update the BIOS in the event that the
BIOS becomes corrupted or if you want to set the BIOS settings back to their
defaults. A reboot occurs automatically after the update is complete. The BIOS code
resides both on the Sun Fire V60x and Sun Fire V65x servers Diagnostics CD and on
the Service Partition in the
from a standalone, bootable floppy diskette See "Updating the Server
Configuration" on page 4-50 for information on how to update the BIOS.
4.11.2.8

Reboot to Service Partition

Selecting this menu item causes a reboot to the service partition.
4.11.2.9

Reboot System

Choosing this menu item causes a reboot, maintaining normal boot device ordering.
4. The update files are on the hard drive service partition.
4-44
Sun Fire V60x and Sun Fire V65x Servers—Troubleshooting Guide • November 2003
3
directory.
C: /FRUSDR
C: /BIOS
4
directory. The BIOS can also be updated

Advertisement