Figure 5-9 Connecting The Dimm Fan Power Cable - Sun Microsystems Sun Fire V60x Manual

Table of Contents

Advertisement

a. Orient the support bars so that the curved bottom aligns with the notches in the
two middle DIMM ejector bars.
b. Gently push each support bar onto the two ejector bars until they are held
firmly in place. Make sure the DIMMs stay securely seated in their sockets.
c. Slide the fan assembly down over the two support bars.
d. The flexible tabs at the top of the support bars lock the fan assembly in place.
3. Connect the DIMM fan cable to the 3-pin header on the server main fan pack (see
Figure 5-9).
to DIMM fan
Connecting the DIMM Fan Power Cable
FIGURE 5-9
4. Replace the server cover.
Chapter 5 Maintaining the Server