3.1.2
Beep Codes
A built-in server speaker indicates failures with audible beeps. See "POST Error
Beep Codes" on page 3-19.
3.1.3
POST Screen Messages
For many failures, the BIOS sends error codes and message to the screen. See "POST
Screen Messages" on page 3-16
3.1.4
System Utilities
The following utilities are available to help troubleshoot system errors:
Platform Confidence Test (PCT). The PCT is used to test major subsystems and
■
analog sensors of the system board.
System Setup Utility (SSU). The SSU is used to read the System Event Log (SEL).
■
3.1.4.1
Platform Confidence Test (PCT)
The PCT consists of up to 31 tests that test the following:
Processor subsystem
■
Memory subsystem
■
Input/output subsystem
■
Management subsystem
■
The PCT supplies three testing levels:
Quick Test. This runs a subset of available tests and identifies processor, memory,
■
cache and hard drives.
Comprehensive Tests. This runs Quick Tests and identifies keyboard, mouse,
■
ports, and controllers.
Comprehensive Tests with Looping. This runs Comprehensive Tests, continually
■
loops through tests until stopped, and enables identification of intermittently
failing FRUs.
For information on how to run the PCT, see "Run Platform Confidence Test (PCT)"
on page 4-31.
3.1.4.2
System Setup Utility (SSU)
The SSU is intended to help with troubleshooting system errors, and can be used to
read the System Event log (SEL).
3-2
Sun Fire V60x and Sun Fire V65x Servers—Troubleshooting Guide • November 2003