Bios Recovery Beep Codes; Table 3-11 Memory 3-Beep And Led Post Error Codes - Sun Microsystems Sun Fire V60x Manual

Table of Contents

Advertisement

Memory 3-Beep and LED POST Error Codes
TABLE 3-11
Debug Port
80h Error
Beep Code
Indicator
3
00h
3
01h
3
02h
3
03h
3
04h
3
05h
3
06h
3
07h
08h
09h
0Ah
0Bh
0Ch
0Dh
3
0Eh
3
0Fh
3.3.2.1

BIOS Recovery Beep Codes

In rare cases, when the system BIOS has been corrupted, a BIOS recovery process
must be followed to restore system operability. During recovery mode, the video
controller is not initialized. One high-pitched beep announces the start of the
recovery process. The entire process takes two to four minutes. A successful update
ends with two high-pitched beeps. In the event of a failure, two short beeps are
generated and a flash code sequence of 0E9h, 0EAh, 0EBh, 0ECh, and 0EFh appears
at the Port 80 diagnostic LEDs (see Table 3-12 on page 3-22).
Diagnostic LED Decoder
(G = green, R = red, A = amber)
MSB
Off
Off
Off
Off
Off
Off
Off
Off
Off
G
Off
G
Off
G
Off
G
G
Off
G
Off
G
Off
G
Off
G
G
G
G
G
G
G
G
Chapter 3 Troubleshooting the Server Using Built-In Tools
Meaning
LSB
Off
Off
No memory was found in the system
Off
G
Memory mixed type detected
G
Off
EDO is not supported
G
G
First row memory test failure
Off
Off
Mismatched DIMMs in a row
Off
G
Base memory test failure
G
Off
Failure on decompressing post
module
G
G
Generic memory error
Off
Off
Off
G
G
Off
G
G
Off
Off
Off
G
G
Off
SMBUS protocol error
G
G
Generic memory error
3-21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sun fire v65x