2.2.4

System Cooling Fans Do Not Rotate Properly

If the system cooling fans are not operating properly, system components could be
damaged.
Check the following:
Is AC power available at the wall outlet?
Is the system power cord properly connected to the system and the wall outlet?
Did you press the power button?
Is the power on light illuminated?
Have any of the fan motors stopped (use the server management subsystem to
check the fan status)?
Are the fan power connectors properly connected to the server board?
Is the cable from the front panel board connected to the server board?
Are the power supply cables properly connected to the server board?
Are there any shorted wires caused by pinched cables or power connector plugs
forced into power connector sockets the wrong way?
If the switches and connections are correct and AC power is available at the wall
outlet, contact your service representative or authorized dealer for help.
2.2.5

Disk Drive Activity Light Does Not Light

Check the following:
Are the disk drive power and signal cables properly installed?
Are all relevant switches and jumpers on the disk drive set correctly?
Is the disk drive properly configured?
Is the disk drive activity light always on? If so, the signal cable may be plugged in
incorrectly.
Use the Setup Utility to make sure that the disk drive is enabled.
If the problem persists, there may be a problem with the disk drive, server board, or
drive signal cable. Contact your service representative or authorized dealer for help.
2.2.6

CD-ROM Drive Activity Light Does Not Light

Check the following:
Are the power and signal cables to the CD-ROM drive properly installed?
Are all relevant switches and jumpers on the drive set correctly?
Is the drive properly configured?
Is the onboard IDE controller enabled?
Is the flex cable between the server board and the backplane installed properly?
2-12