Table of Contents

Advertisement

2. Install the flex cable retention clip on the SCSI backplane as shown in Figure 5-46.
FIGURE 5-46
3. Install the screw-in blue plastic retention clip to hold the flex cable connector in
place on the server board.
4. Connect both ends of the SCSI cable (Figure 5-44, D), making sure it routes
through the air baffle notch next to the power supply.
5. Install the front panel cable (Figure 5-44, F) between the front panel and the SCSI
backplane.
6. Install the USB cable (Figure 5-44, E).
a. Connect the USB Cable to the front panel board.
b. Connect the USB cable to the main board.
c. Route the USB cable under the black plastic flap and hooks at the top of the fan
module to keep it securely in place.
Note – The Comprehensive Test should be run after changing any FRU, CRU, or
adding an optional component. See "Run Platform Confidence Test (PCT)" on
page 4-31
5-70
Sun Fire V60x and Sun Fire V65x Servers—Troubleshooting Guide • November 2003
Installing the Backplane Retention Clip