5. Place the edge connector end of the replacement module onto the chassis floor and
slide it toward the front of the chassis until the edge connector is fully inserted in
the power distribution board connector.
6. Make sure that the rear of the power supply is fully seated on the chassis floor
and in front of the raised guides.
7. Replace the chassis cover.
Note – The Comprehensive Test should be run after changing any FRU, CRU, or
adding an optional component. See "Run Platform Confidence Test (PCT)" on
page 4-31.
5.5.6.2

Sun Fire V65x Server Power Supply

The default configuration for the Sun Fire V65x server is a single 500-watt power
supply. Optionally, you can add a second power supply module to provide a
redundant, 1+1 system.
Caution – If you do not have the second, redundant power supply module, you
must take the server out of service before replacing the single module.
To replace a power supply:
1. Squeeze the module handle to depress the latch (Figure 5-27, panel 1).
2. Rotate the handle down while pulling the module toward you
(Figure 5-27, panel 2).
3. As you pull the module out, support the module with your free hand.
4. Insert a new power supply module in the bay.
5. Grip the module handle, rotate it down, and push the module into the bay.
6. When the module is nearly all of the way in, the handle will rotate up. At this
time, push firmly on the front of the handle to lock the latch.
5-34
Sun Fire V60x and Sun Fire V65x Servers—Troubleshooting Guide • November 2003