Run Baseboard Management Controller (Bmc) Firmware Update; Run Hsc Firmware Update - Sun Microsystems Sun Fire V60x Manual

Table of Contents

Advertisement

Comprehensive Test With Continuous Looping
This test performs the same test as the Comprehensive Test, but runs continuously
until stopped. To stop the testing and display the test pass count, press Ctrl + Break.
The number of successful test loops executed is shown as "Pass Count = n" at the
upper right side of the screen.
The run time for this test is approximately 15 to 20 minutes per pass, depending on
the amount of memory installed.
Note – The Comprehensive Test should be run after changing any FRU, CRU, or
adding an optional component.
4.11.2.4
Run Baseboard
Update
Use this menu selection to update the Baseboard Management Controller (BMC)
firmware. The BMC code resides both on the Sun Fire V60x and Sun Fire V65x
servers Diagnostics CD and on the Service Partition in the
BMC firmware can also be updated from a standalone, bootable floppy diskette
4.11.2.5

Run HSC Firmware Update

Use this menu selection to update the hard disk controller firmware. The hot-swap
controller (HSC) code resides both on the Sun Fire V60x and Sun Fire V65x servers
Diagnostics CD and on the Service Partition in the C: /HSC directory. The HSC
firmware can also be updated from a standalone, bootable floppy diskette.
2. The baseboard refers to the server Main Board.
3. The update files are on the hard drive service partition.
2
Management Controller (BMC) Firmware
3
Chapter 4 Powering On and Configuring the Server
directory. The
C: /BMC
4-43

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sun fire v65x

Table of Contents