5.6.2.3

Sun Fire V65x Server Cable Kit Removal

Before removing the cover to work inside the system, observe the safety guidelines
previously given.
To remove cables, remove the cover and refer to Figure 5-44 and Figure 5-44 when
following these steps:
1. Insert your fingers under the blue plastic loops on the full-height PCI riser card
and pull the riser card straight up out of the chassis.
2. Unscrew the air baffle screw and remove the floppy/FP/IDE flex cable retention
clip.
3. Remove the air baffle.
4. Unscrew and remove the plastic retention clip that holds the flex cable connector
to the SCSI backplane.
5. Remove the floppy/FP/IDE flex circuit cable that runs from the connector on the
server board to the connector on the backplane.
6. Remove the front panel cable that runs from the front panel board to the
backplane.
7. Remove the USB cable that runs from the connector on the front panel board,
through the clips on top of the fan module, to the connector on the server main
board.
8. Remove the SCSI cable that runs from the SCSI backplane to the server board.