4.10 Warm-up Time

When nominal voltage (100V,120V,220V) is applied, ready temperature (Fuser Stand-by) is reached within
30 seconds after command is given by the controller.
Reference: Measured at 22°C, 55% RH, nominal voltage.

4.11 FPOT (First Print Output Time)

FPOT time of the printer is shown in the table below.
The time required for the first sheet of paper to be delivered after the START command is given is
calculated on the following conditions (rounded to one decimal place).
• IOT performance that the controller does not have IOT wait.
• This value is indicated by either of two described below depending on the status of Motor On and
Fuser.
1. ROS RDY t
2. ROS OFF t
• Paper is A4 SEF
• Except when process control is operating*1 / when Fuser Cool down*2
• Paper mode is plain paper mode.
• Paper feeding is Tray1 (paper tray which locates at the bottom of the printer)
• Measurement environment is at 22 °C / 55%RH rated voltage.
*1:Process controller operation is process controls such as TC control, electric potential control,
cleaning cycle, registration control, and so on. Sometimes, the engine stops feeding papers for
a certain period of time while continuous printing for these operations.
*2:The print may not start for a certain time after receiving the start command due to prior job
running conditions.
Process speed
Full speed
Half speed
1/3 speed
FPOT of paper fed from trays other than is added following values to above ROS RDY t
t
.
off
Process speed
Full speed
Half speed
1/3 speed
*3 Tray2 : First tray of option Feeder
*4 Tray3 : Second tray of option Feeder
8-502
: ROS Motor Ready (steady-status rotation) and Fuser Ready
on
: ROS Motor Off (at stopping) and Fuser Ready temperature
off
In Simplex mode
ROS RDY t
ROS OFF t
on
8.0
14.5
21.0
MSI
Feeder Unit(Tray2) *3
-0.3 sec
-0.6 sec
-0.9 sec
FPOT(sec)
ROS RDY t
off
13.5
13.5
20.0
24.5
26.5
35.5
Option
+0.9 sec
+1.8 sec
+2.7 sec
In Duplex mode
ROS OFF t
on
19.0
30.0
41.0
on
Option
Feeder Unit (Tray3) *4
+1.8 sec
+3.5 sec
+5.3 sec
off
and ROS OFF