2.5 Input Test
2.5.1 Executing input test
Click the [Diagnostic Input Test] button, and the following screen will appear.
The screen will vary according to the conditions of the sensors and switches.
The ON or OFF condition of digital sensors and switches can be checked from the color of indicators on the
side of each name.
ON: Green OFF: Red
For analog devices, A/D converted values are displayed.
For the relation between A/D converted values and data, refer to the Input test
Readme.txt file in the folder where the Diagnostic Commander has been installed.
2.5.2 Type of input test
Two types, digital input test and analog input test, are provided.
The digital input tests that can be checked are as listed below.
Name
Inter Lock Sensor
OHP Sensor
Fuser Ready
ROS Ready
Parts Name/Function
PWBA DRV HBN is installed
KIT SENSOR OHP
–
–
Chapter 2 Operation of Diagnostics
ON Condition
Front cover open
Paper present
Under printing
Under printing
2-125