2.6 Output Test
Never touch the high voltage output parts and live parts when high voltage is
outputted.
Never touch the driving parts when the driving parts are operating.
If it continues turning on Toner Motor (Yellow/Magenta/Cyan/Black), since a toner will
continue being supplied, don't turn on for a long time.
Before executing the output test, be sure to read the "Caution" and "Prohibition"
described in the Output test Readme.txt file in the folder where the Diagnostic Com-
mander has been installed
For the items attached with <Warning!> or <Caution!> in the checking method, refer to
the "WARNING" and "CAUTION" mentioned above to prevent problems.
2.6.1 Executing output test
Click the [Diagnostics Output Test] button, and the following screen will appear.
Click the check box on the left side of the item to be operated, and "√ "is displayed in the check box and the
operation starts.
If clicking again the check box, the check is cancelled and the operation stops. However, some parts will
stop automatically when the specified time elapsed.
For the items that have the pull-down menu, select the menu to be executed.
Chapter 2 Operation of Diagnostics