Example
To test the cable on ports 1 to 4, and 8:
DGS-3420-28TC:admin# cable_diag ports 1:1-1:10,1:21
Command: cable_diag ports 1:1-1:10,1:21
Perform Cable Diagnostics ...
Port
Type
------
----------
1:1
1000BASE-T
1:2
1000BASE-T
1:3
1000BASE-T
1:4
1000BASE-T
1:5
1000BASE-T
1:6
1000BASE-T
1:7
1000BASE-T
1:8
1000BASE-T
1:9
1000BASE-T
1:10
1000BASE-T
1:21
1000BASE-X
DGS-3420-28TC:admin#
Link Status
Test Result
-------------
----------------------------
Link Up
OK
Link Up
OK
Link Down
Shutdown
Link Down
Shutdown
Link Down
Unknown
Link Down
Pair 1 Crosstalk at
Pair 2 Crosstalk at
Pair 3 OK
Pair 4 OK
Link Down
NO Cable
Link Down
Pair 1 Open
Pair 2 Open
Pair 3 OK
Pair 4 OK
Link Down
Pair 1 Short
Pair 2 Short
Pair 3 OK
Pair 4 OK
Link Down
Pair 1 Unknown
Pair 2 Short
Pair 3 OK
Pair 4 OK
Link Up
Unknown
30M
30M
at 110M
at 110M
at
16M
at
16M
at
50M
at
50M
at
5M
at
5M
at 110M
at 110M
at
5M
at 110M
at 110M