Pseudo Rbt Transmission Level At Time Of Fax/Tel Switchover>; Answering Machine Connection Function Signal Detection Time>; V.21 Low-Speed Flag Preamble Identification Length>; Count Type Select > - Canon iR2020 Series Service Manual

Canon ir2020/2016 series service manual
Hide thumbs Also See for iR2020 Series:
Table of Contents

Advertisement

Chapter 14
Use it to set the CNG detention level for a fax/tel switchover.
14.5.12 <024: pseudo RBT transmission level at time of fax/tel switchover>
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to set the pseudo transmission level for a fax/tel switchover.
14.5.13 <025: Answering machine connection function signal detection time>
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Sets the signal detection time for the answering machine connection function operation. When the answering machine connection function is operating, if the func-
tion does not operate normally because the fax does not detect CNG signal sent from the line, raise this parameter to increase the signal detection time.
14.5.14 <027: V.21 low-speed flag preamble identification length>
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to detect the time of detection after which command analysis is started after detecting V.21 low-speed command preambles continuously for a specific period
of time.
14.5.15 <056 - 061: Count type select >
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to confirm the count type indicated on the Counter Check screen, which appears in response to a press on the Counter key.
When '0' is selected, count type will not be indicated.
No.56: Use it to indicate the type of software counter 1 of the control panel. The type of soft counter 1 cannot be changed.
No.57: Use it to change the type of soft counter 2* of the control panel to suit the needs of the user.
No.58: Use it to change the type of soft counter 3* of the control panel to suit the needs of the user.
No.59: Use it to change the type of soft counter 4* of the control panel to suit the needs of the user.
No.60: Use it to change the type of soft counter 5* of the control panel to suit the needs of the user.
No.61: Use it to change the type of soft counter 6* of the control panel to suit the needs of the user.
*:The default type settings of soft counter is different from models.
<Soft Counter Specifications>
The soft counters are classified a follows in terms of input numbers:
100s: total
200s: copy
300s: print
400s: copy + print
500s: scan
700s: received file print
800s: report pint
900s: transmitted scan
Guide to the Table
- 1:Count sheets of all sizes by one.
- 2:Count sheets of the large size by two.
- C:full color
- Bk:black mono
- L:large size (larger than A4/LTR)
- S:small size (A4/LTR or smaller)
MEMO:
To make a change so that B4 papers (for print) will be counted as large-size, use service mode: make the following selections, and change bit 0 to '1': #SSSW>SW33.
To make a change so that B4 papers (for scan) will be counted as large-size, use service mode: make the following selections, and change bit 2 to '1': #SSSW>SW33.
Seri
Counter type
al
No.
on
cou
nter
chec
k
scre
en
101 Total1
102 Total2
103 Total (L)
104 Total (S)
108 Total (Bk1)
109 Total (Bk2)
112 Total (Bk/L)
113 Total (Bk/S)
114 Total1 (2-sided)
115 Total2 (2-sided)
116 L (2-sided)
117 S (2-sided)
126 TotalA1
127 TotalA2
128 TotalA (L)
129 TotalA (S)
132 TotalA (Bk1)
14-16
Print system
Bk 1-sided L
Bk 1-sided S
Local
PDL
FAX
Repo
Local
copy
print
print
rt
copy
print
1
1
1
1
1
2
2
2
2
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
1
1
1
1
1
1
1
1
1
2
2
2
1
1
1
1
1
1
Bk 2-sided L
PDL
FAX
Repo
Local
PDL
print
print
rt
copy
print
print
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Bk 2-sided S
FAX
Repo
Local
PDL
FAX
print
rt
copy
print
print
print
1
1
1
1
1
2
2
1
1
1
1
1
1
1
1
0011-1799
0011-1800
0011-1801
0011-1858
Repo
rt
print
1
1
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ir2016 series

Table of Contents