14.5.3 <005: NCC pause length (pre-ID code)>
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to set the length of the pause automatically entered between access code and ID code when the NCC (New Common Carrier) line is used for dialing.
14.5.4 <006: NCC pause length (post-ID code)>
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to set the length of the pause automatically entered between ID code and telephone number of the other party when the NCC (New Common Carrier) line is
used for dialing.
14.5.5 <010: line connection identification length>
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to set the time for identifying the line connection. Raise this parameter if errors occur frequently at time of communication because of the condition of the line.
Memo:
Any of the following error codes may be indicated because of the condition of the line
##0005, ##0018
The line condition identification time is between when the dial signal is transmitted and when the line condition is cut for the transmitting party, while it is between
when the DIS signal is transmitted and when the line is cut for the receiving party.
14.5.6 <011: T.30 T1 timer (for reception)>
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Set the T1 timer for the receiver (wait time after DIS transmission starts until a significant signal is received).
14.5.7 <013: T.30 EOL timer>
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Set it so that the 1-line transmission time is longer for reception to prevent reception errors caused by a long data length per line (e.g., computer FAX).
14.5.8 <016: time length to first response at time of fax/tel switchover>
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Allows setting of the time from seizing the line till pseudo RBT is sent, when the Fax/ Tel switching function is operating.
14.5.9 <017: pseudo RBT signal pattern ON time length><018: pseudo RBT signal pattern OFF time length (short)><019:
pseudo RBT signal pattern OFF time length (long)>
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to set the pattern of the pseudo RBT signal transmitted at time of a fax/tel switchover.
14.5.10 <020: pseudo CI signal pattern ON time length><021: pseudo CI signal pattern OFF time length (short)><022:
pseudo CI signal pattern OFF time length (long)>
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to set the pseudo CI signal pattern transmitted at time of a fax/tel switchover.
14.5.11 <023: CNG detention level for fax/tel switchover>
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to set the CNG detention level for a fax/tel switchover.
14.5.12 <024: pseudo RBT transmission level at time of fax/tel switchover>
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to set the pseudo transmission level for a fax/tel switchover.
14.5.13 <025: Answering machine connection function signal detection time>
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Sets the signal detection time for the answering machine connection function operation. When the answering machine connection function is operating, if the func-
tion does not operate normally because the fax does not detect CNG signal sent from the line, raise this parameter to increase the signal detection time.
14.5.14 <027: V.21 low-speed flag preamble identification length>
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to detect the time of detection after which command analysis is started after detecting V.21 low-speed command preambles continuously for a specific period
of time.
14.5.15 <056 - 061: Count type select >
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to confirm the count type indicated on the Counter Check screen, which appears in response to a press on the Counter key.
When '0' is selected, count type will not be indicated.
No.56: Use it to indicate the type of software counter 1 of the control panel. The type of soft counter 1 cannot be changed.
No.57: Use it to change the type of soft counter 2* of the control panel to suit the needs of the user.
No.58: Use it to change the type of soft counter 3* of the control panel to suit the needs of the user.
14-14
0011-1789
0011-1790
0011-1791
0011-1792
0011-1793
0011-1795
0011-1796
0011-1797
0011-1798
0011-1799
0011-1800
0011-1801
0011-1858

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ir2016 series

Table of Contents