Chapter 8
spacer (R) [3] are pressed against the rib [4] of the flange cap.
[1]
[2]
9) Release the claw [1] of the pressure cam, remove the pressure cam [2]
from the pressure shaft, and then pull out the pressure shaft [3] in the
direction of the arrow.
[3]
When installing the pressure cam, position it inside the bent portion [1] of
the side plate as shown below.
8-12
F-8-36
[3]
[4]
F-8-37
[2]
[1]
F-8-38
[1]
10) Remove the delivery roller unit [1], and then remove the fixing film unit
[2].
[2]
11) Remove the spacer (F) [1] and spacer (R) [2] by sliding them.
[1]

8.4.2.7 Removing the Pressure Roller

iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
1) Raise the claw [1] of the fixing unit inlet guide, and remove the slide the
fixing unit inlet guide [2] by sliding it in the direction of the arrow.
2) Remove the E-ring [1] and gear [2], and then remove the pressure roller
[3].
F-8-39
[1]
F-8-40
[2]
F-8-41
[2]
[1]
F-8-42
0010-9942