Chapter 13
No.
##0770
##0772
##0773
##0774
##0775
##0777
##0778
##0779
##0780
##0782
##0783
##0784
##0785
##0787
##0788
##0789
##0790
##0791
##0792
##0793
##0794
##0795
13-10
Tx/Rx
Description
[Tx]
at time of ECM transmission, no meaningful signal is received after transmission of
EOR-NULL, causing the procedural signal to be transmitted more than specified.
[Tx]
at time of ECM transmission, DCN is received after transmission of EOR-NULL.
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than
specified after transmission of EOR-NULL, or T5 time-out (60 sec) has occurred.
[Tx]
at time of ECM transmission, ERR is received after transmission of EOR-NULL.
[Tx]
at time of ECM transmission, no meaningful signal is received after transmission of
EOR-MPS, causing the procedural signal to be transmitted more than specified.
[Tx]
at time of ECM transmission, DCN is received after transmission of EOR-MPS.
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than
specified after transmission EOR-MPS, or T5 time-out (60 sec) has occurred.
[Tx]
at time of ECM transmission, ERR is received after transmission of EOR-MPS.
[Tx]
at time of ECM transmission, no meaningful signal is received after transmission of
EOR-EOM, causing the procedural signal to be transmitted more than specified.
[Tx]
at time of ECM transmission, DCN is received after transmission of EOR-EOM.
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than
specified after transmission of EOR-EOM, or T5 time-out (60 sec) has occurred.
[Tx]
at time of ECM transmission, ERR is received after transmission of EOR-EOM.
[Tx]
at time of ECM transmission, no meaningful signal is received after transmission of
EOR-EOP, causing the procedural signal to be transmitted more than specified.
[Tx]
at time of ECM transmission, DCN is received after transmission of EOR-EOP.
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than
specified after transmission of EOR-EOP, or T5 time-out (60 sec) has occurred.
[Tx]
at time of ECM transmission, ERR is received after transmission of EOR-EOP.
[Rx]
at time of ECM reception, ERR is transmitted after transmission of EOR-Q.
[Tx/Rx]
while ECM mode procedure is under way, a signal other than a meaningful signal
is received.
[Rx]
at time of ECM reception, PPS-NULL cannot be detected over partial page
processing.
[Rx]
at time of ECM reception, no effective frame is received while high-speed signal
reception is under way, thus causing time-out.
[Tx]
at time of ECM reception, PPR with all 0s is received.
[Tx/Rx]
a fault has occurred in code processing for communication.