[2].
[2]
7.5.8.3 Removing the Feed Guide
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
1) Remove the two screws [1], and then remove the feed guide [2].
7.5.8.4 Removing the Multifeeder Paper Presence/
Absence Sensor
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
1) Remove the two claws [1]. Remove the connector [2], and then remove
the multifeeder paper presence/absence sensor [3].
7.5.9 Manual Feed Pickup Solenoid
7.5.9.1 Removing the Drum Unit
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
1) Open the front cover [1].
2) Turn the developer pressure release lever [2] clockwise, and then open the
left door [3].
3) Draw out the drum unit [4].
7-14
[1]
[1]
F-7-40
[2]
[1]
F-7-41
[3]
[2]
[1]
F-7-42
[3]
[2]
To prevent exposure to light, cover the drum with several sheets of copy
paper and place it in a safe place.
0011-0674
Open the left door fully to prevent the damage to the drum unit
7.5.9.2 Removing the Transfer Registration Unit
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
1) Remove the four screws [1], and then remove the transfer registration unit
[2].
0011-0675
7.5.9.3 Removing the Feed Guide
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
1) Remove the two screws [1], and then remove the feed guide [2].
0011-2965
7.5.9.4 Removing the Multifeeder Connector Cover
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
1) Detach the multifeeder connector cover [1], and then disconnect the three
connectors [2].
[4]
[1]
F-7-43
[1]
[2]
[1]
F-7-44
[2]
[1]
F-7-45
0011-2966
0011-2967
0011-1051