13.1 Error Code Table

13.1.1 List of Error Codes

iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i

13.2 Error Code Details

13.2.1 Error Code Details
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
MEMO:
In case of iR2020i/iR2016i, the detail code of the error code of this machine can be confirmed in the following service mode.
Service mode>ERROR DISPLAY
E000
Detail
Error Code
Code
E000
0000
Fixing temperature abnormal rise
0000
Fixing unit temperature rise detection (by main thermistor)
E001
0001
Fixing unit temperature rise detection (by sub thermistor)
E002
0000
Fixing unit temperature insufficient rise
0000
Low fixing temperature detection after standby (by main thermistor)
E003
0001
Low fixing temperature detection after standby (by sub thermistor)
E007
0000
Fixing film rotation error
E010
0000
Main motor rotation error
0001
Waste toner full detection
E019
0002
Waster toner full detection sensor failure
E052
0000
Duplex unit connection error
E100
0000
BD cycle out of range
E197
0000
Erroneous communication with printer engine
E500
0001
Finisher communication error
E520
0000
Offset error
E531
0000
Stapling error
0001
Paper surface not detected (standard tray)
0002
Not moved within the specified time (standard tray)
E540
0003
Sensor not reached within 3 seconds (standard tray)
0005
Encoder clock failure (standard tray)
0001
Paper surface not detected (optional tray)
0002
Not moved within the specified time (optional tray)
E542
0003
Sensor not reached within 3 seconds (optional tray)
0005
Encoder clock failure (optional tray)
E575
0000
Stack delivery error
E584
0000
Shutter failure
E716
0000
Erroneous communication with optional cassette
0000
Erroneous communication with card reader (serial communication)
E719
0002
Erroneous communication with coin vender (serial communication)
E733
0000
Erroneous communication between controller and printer
E736
0000
CCU communication error
E739
0000
Erroneous communication between controller and network board
0001
Language file/boot ROM/USB memory error
0002
E744
0003
0004
E805
0000
Fan failure
E808
0000
Fixing drive circuit failure
Display
Detail Code
Main Cause/Symptom
Code
0000
Startup error
The temperature detected by the main
or sub thermistor does not rise to the
specified value during startup control.
T-13-1
Error Name/Explanation of Error
T-13-2
Countermeasure
- Check the fixing film connector.
- Replace the fixing film unit.
- Replace the DC controller PCB.
Chapter 13
0011-2570
0011-2580
13-1