If 'yes' is selected, the serial No. will be indicated.
If 'no' is selected, on the other hand, the serial No. will not be indicated.
14.3.11.4 Detailed Discussions of Bit 2
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to specify whether B4 paper (Scan) should be counted as large-size paper.
If 'yes' is selected, B4 paper will be counted as large-size paper.
If 'no' is selected, on the other hand, B4 paper will be counted as small-size paper.
14.3.11.5 Detailed Discussions of Bit 3
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Select whether to switch the counter display type in effect in Japan to the conventional or new type. Select "Yes" to display counters in the new type. Select "No"
to display counters in the conventional type.
14.3.12 SSSW-SW34
14.3.12.1 List of Functions
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Bit
0
1
2
3
4
5
6
7
The default setting of this SSSW varies depending on the destination of the product.
Product for Japan: 00000000
Product for countries in Euro zone: 00000011
Products for other countries/regions: 00000001
14.3.12.2 Detailed Discussions of Bit 0
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
You can select whether a waste toner full warning is to be displayed.
When "1" is selected, a waste toner full warning is displayed.
When "0" is selected, a waste toner full warning is not displayed.
14.3.12.3 Detailed Discussions of Bit 1
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Select whether to display the waste toner full warning as a drum replacement required message or as E019 displayed on an operator call. Select 1 to display a rum
replacement required message on an operator call. Select 0 to display E019 on an service call.
14.4 Setting of Menu Switch (Menu)

14.4.1 Menu Switch Composition

iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
No.
005
006
007
008
009
010
14.4.2 <No.005 NL equalizer>
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to enable-disable the NL equalizer.
If errors occur often during communication because of the condition of the line, enable (ON) the NL equalizer.
Any of the following error codes may be indicated at time of transmission because of the line condition:
##100, ##101, ##102, ##104, ##201, ##281, ##282, ##283, ##750, ##755, ##765, ##774, ##779, ##784, ##789
Any of the following error codes may be indicated at time of transmission because of the line condition:
Function
Display the waste toner full
warning
Switch the waste toner full
warning
Not used
Not used
Not used
Not used
Not used
Not used
Function
Range of settings
NL equalizer
1: ON, 0: OFF
telephone line monitor
0:DIAL, 1:SERVICEMAN1, 2:SERVICEMAN2, 3:OFF
transmission level (ATT)
from 0 to 15 (ex: 15= -15 dBm)
V.34 modulation speed upper
0:3429, 1:3200, 2:3000, 3:2800, 4:2743, 5:2400
limit
V34 data speed upper limit
0:33.6 kbps, 1:31.2 kbps, 2:28.8 kbps, 3:26.4 kbps, 4:24.0 kbps,
5:21.6 kbps, 6:19.2 kbps, 7:16.8 kbps, 8:14.4 kbps, 9:12.0 kbps,
10:9.6 kbps, 11:7.2 kbps, 12:4.8 kbps, 13:2.4 kbps
Frequency of pseudoring signal
0:50 Hz, 1:25 Hz, 2:17 Hz
T-14-14
1
0
YES
NO
Drum replacement required
E019 displayed on an service
message displayed on an
call
operator call
-
-
-
-
-
-
-
-
-
-
-
-
T-14-15
Chapter 14
0011-1764
0011-1765
0011-1766
0011-3594
0011-1767
0011-1768
0011-1770
14-13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ir2016 series

Table of Contents