005: Ncc Pause Length (Pre-Id Code); 006: Ncc Pause Length (Post-Id Code); 011: T.30 T1 Timer (For Reception); 013: T.30 Eol Timer - Canon MF4690 - ImageCLASS B/W Laser Service Manual

Mf4600 series
Hide thumbs Also See for MF4690 - ImageCLASS B/W Laser:
Table of Contents

Advertisement

Chapter 14
14.5.2 <002: RTN transmission condition (1)><003: RTN transmission condition (2)><004: RTN transmission condition (3)>
Use it to set RTN signal transmission conditions. Raise these parameters for more lenient conditions if errors occur frequently at time of reception because of trans-
mission of the RTN signal.
Memo:
Any of the following error codes may be indicated at time of reception because of RTN signal transmission
##0104, ##0107, ##0114, ##0201
RTN signal transmission condition (1) affects the ratio of error lines to the total number of lines per single page of received images.
RTN signal transmission condition (2) affects the standard value (*2) of burst errors (*1).
RTN signal condition (3) affects the number of errors not reaching the standard value of burst errors.
*1: transmission error occurring cover several lines.
*2: for instance, if '15' is set, a single burst error will represent an error occurring continuously cover 15 lines.
If any of these lines is detected while an image signal is being received, the RTN signal will be transmitted after receiving the protocol signal of the transmitting
party. Higher parameters restrict the transmission of the RTN signal.
14.5.3 <005: NCC pause length (pre-ID code)>
Use it to set the length of the pause automatically entered between access code and ID code when the NCC (New Common Carrier) line is used for dialing.
14.5.4 <006: NCC pause length (post-ID code)>
Use it to set the length of the pause automatically entered between ID code and telephone number of the other party when the NCC (New Common Carrier) line is
used for dialing.
14.5.5 <010: line connection identification length>
Use it to set the time for identifying the line connection. Raise this parameter if errors occur frequently at time of communication because of the condition of the line.
Memo:
Any of the following error codes may be indicated because of the condition of the line
##0005, ##0018
The line condition identification time is between when the dial signal is transmitted and when the line condition is cut for the transmitting party, while it is between
when the DIS signal is transmitted and when the line is cut for the receiving party.
14.5.6 <011: T.30 T1 timer (for reception)>
Set the T1 timer for the receiver (wait time after DIS transmission starts until a significant signal is received).
14.5.7 <013: T.30 EOL timer>
Set it so that the 1-line transmission time is longer for reception to prevent reception errors caused by a long data length per line (e.g., computer FAX).
14.5.8 <016: time length to first response at time of fax/tel switchover>
Allows setting of the time from seizing the line till pseudo RBT is sent, when the Fax/ Tel switching function is operating.
14.5.9 <017: pseudo RBT signal pattern ON time length><018: pseudo RBT signal pattern OFF time length (short)><019:
pseudo RBT signal pattern OFF time length (long)>
Use it to set the pattern of the pseudo RBT signal transmitted at time of a fax/tel switchover.
14.5.10 <020: pseudo CI signal pattern ON time length><021: pseudo CI signal pattern OFF time length (short)><022:
pseudo CI signal pattern OFF time length (long)>
Use it to set the pseudo CI signal pattern transmitted at time of a fax/tel switchover.
14.5.11 <023: CNG detention level for fax/tel switchover>
Use it to set the CNG detention level for a fax/tel switchover.
14.5.12 <024: pseudo RBT transmission level at time of fax/tel switchover>
Use it to set the pseudo transmission level for a fax/tel switchover.
14.5.13 <025: Answering machine connection function signal detection time>
Sets the signal detection time for the answering machine connection function operation. When the answering machine connection function is operating, if the func-
tion does not operate normally because the fax does not detect CNG signal sent from the line, raise this parameter to increase the signal detection time.
14.5.14 <027: V.21 low-speed flag preamble identification length>
Use it to detect the time of detection after which command analysis is started after detecting V.21 low-speed command preambles continuously for a specific period
of time.
14.5.15 <056 - 061: Count type select >
Use it to confirm the count type indicated on the Counter Check screen, which appears in response to a press on the Counter key.
When '0' is selected, count type will not be indicated.
No.56: Use it to indicate the type of software counter 1 of the control panel. The type of soft counter 1 cannot be changed.
No.57: Use it to change the type of soft counter 2* of the control panel to suit the needs of the user.
No.58: Use it to change the type of soft counter 3* of the control panel to suit the needs of the user.
14-14
No.
Item
059
Display the type of soft counter 4
060
Display the type of soft counter 5
061
Display the type of soft counter 6
Range of settings
0 to 999
0 to 999
0 to 999
0016-2050
0016-2051
0016-2052
0016-2053
0016-2054
0016-2055
0016-2057
0016-2058
0016-2059
0016-2060
0016-2061
0016-2062
0016-2063
0016-2064