13-6.

Main Hopper Toner Replenishing Mechanism

• The Main Hopper Toner Replenishing Motor gives the drive for supplying toner from the
Toner Bottle to Sub Hopper.
• Toner is replenished each time the Sub Hopper Toner Empty Switch (S4) provided in the
Sub Hopper is actuated and deactuated.
Main Hopper Toner
Replenishing Motor M6
Electrical Component
M6
S4
Toner Bottle
Energized/
Control Signal
Actuated
PJ15A-1B
L
PJ3A-15B
L
M-27
Sub Hopper
Sub Hopper
Magnet
Sub Hopper Toner Empty
Switch S4
Deenergized/
Wiring Diagram
Deactuated
H
H
4011M020AA
1171M021AA
5-F
5-H