Minolta Di251 Service Manual page 163

Hide thumbs Also See for Di251:
Table of Contents

Advertisement

A
Main scannning direction
1
2
3
4
5
6
7
8
9
0
#
C
Rev. 11..0.0/03.01
7. Measure margins A and B on the copy.
Standard Values:
A4C 10.0 mm ±2.0 mm
Letter C 10.0 mm ±2.0 mm
If the measured width is not within the
standard values, use the following procedure
for adjustment.
8. Touch "OK" to complete the setting.
9. Touch the key representing the drawer
selected as the paper source.
10. After pressing the Clear key, you can change
the value using the key pad.
Use the * key to change between + and -.
11. Touch "OK" to complete the setting.
12. Make another test copy and check the image
once again.
I-75
Di251/Di351

Advertisement

Table of Contents
loading

This manual is also suitable for:

Di351

Table of Contents