Minolta Di251 Service Manual page 224

Hide thumbs Also See for Di251:
Table of Contents

Advertisement

(6)
Registration (FD) (Printer)
Requirement
A
Specification
10 ±2.0 mm
NOTE
• This adjustment must be made when the PH Unit has been replaced and after Registra-
tion (CD) (Printer) has been made.
Adjustment Procedure
1. Call the Adjust Mode to the screen.
2. Touch "Printer" and "Registration (FD)", in that order.
3. Touch "Test Print".
4. Press the Start key.
Paper will be fed from the 1st Drawer and a test pattern will be produced.
5. Check to see if width A on the test pattern meets the specifications.
If width A falls outside the specified range, perform the following steps for adjustment.
6. Touch "END" to recall the Registration (FD) screen.
7. Press the Clear key to clear the current setting value.
Adjust so that width A on the test pattern output falls
within the following range.
4011D097AA
Adjust Mode
Registration (FD)
D-43
Setting Range
25-cpm copier: -26 to +26
35-cpm copier: -19 to +19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Di351

Table of Contents