Removal of the Scanner Drive Cables
1. Remove the Original Glass.
2. Remove the Scanner.
3. Remove the Left Upper Cover and Left IR Cover.
Rear
Front
4. Unhook the spring at the end of the cable from
the front hook and remove the cable guide.
Cable
5. Unhook the spring at the end of the cable from
Guide
the rear hook.
4011D042AA
6. Remove one screw, unplug one connector, and
remove the Original Size Detecting Sensor.
Option for the inch areas
4011D043AA
7. Remove the cover.
See step 2 of "(2) Removal of the CCD Unit" of "2-
5. OPTICAL SECTION."
8. Remove four screws and the Reinforcement
Bracket.
4011D044AD
9. Snap off one retaining ring E type and remove
one mounting screw from the front pulley and
slide the pulley to the rear.
4011D045AA
10. Snap off one retaining ring E type and remove
one mounting screw from the rear pulley and
slide the pulley to the front.
11. Remove the Scanner Drive Cable, hook end first.
4011D046AA