Minolta Di251 Service Manual page 334

Hide thumbs Also See for Di251:
Table of Contents

Advertisement

(2)
C0214: Abnormal image transfer voltage
Power Supply Unit PU1
High Voltage Unit PU2
DC24 V
GND
PWB-A
PJ15A-4A (P.C./I.T. REM)
PJ15A-3A (I.T. CONTROL)
PJ15A-1A (MONITOR)
C0214
Step
1
The voltage across CN11-1 on the side of
Power Supply Unit and GND is DC24 V.
The voltage across CN11-2 on the side of
Power Supply Unit and GND is DC5 V.
2
The voltage across CN17-12 on the side of
Master Board and GND remains DC1.2 V or
less while the malfunction code is being dis-
played.
3
The voltage across CN17-15 on the side of
Master Board and GND remains DC0.9 V or
more while the malfunction code is being dis-
played.
Relevant Electrical Parts
Master Board PWB-A
CN11
1
12
2
11
11
2
12
1
CN17
1
15
12
4
13
3
14
2
15
1
Check
T-36
PU1
PJ9PU1-1 (DC5 V)
PJ9PU1-2 (GND)
PU2
CN1PU2-1 (DC24 V)
CN1PU2-2 (GND)
CN1PU2-3 (GND)
CN1PU2-4 (DC5 V)
CN2PU2-4 (P.C./I.T. REM)
CN2PU2-5 (I.T. CONTROL)
CN2PU2-7 (MONITOR)
Result
Action
NO
Change Power Supply
Unit.
YES
Change Master Board.
YES
Change Master Board.
NO
Change High Voltage Unit.
4011T533AA

Advertisement

Table of Contents
loading

This manual is also suitable for:

Di351