External / BATTM Battery Connection
(1) Connect the BATT CA EXT cable to the batteries as shown below.
(2) Mount the battery units (24V DC, 24AH per unit) into the Battery Module (BATTM), if the
BATTM required.
(3) Plug the BATT CA EXT connector into the BATT1 connector on the PZ-PW121 card in PIM0
or PIM4.
NOTE:
Screws are attached to the BATTM.
DIMENSION OF BATTERY
175 mm
(6.9 inch)
125 mm
(4.9 inch)
165 mm
(6.5 inch)
Recommended Batteries
Yuasa NP-24-12B
Matsushita LCL-12V-24
2
NEAX2000 IVS
Installation Procedure Manual
ND-70928 (E), Issue 1.0
Figure 2-39 Battery Mounting into BATTM
TO BATT1 CONNECTOR
ON PZ-PW121
IN PIM0/PIM4
BATT CA EXT
CHAPTER 2 INSTALLATION
External / BATTM Battery Connection
BATTERY UNIT
(24V DC, 24AH)
BATTERY UNIT
(24V DC, 24AH)