19-inch Rack Mounting Installation

Start
Checkup
before installation
Detaching
Side Cover/Side Panel
One PIM
Configuration
Multiple-PIM
Configuration
Checking
End
2
NEAX2000 IVS
Installation Procedure Manual
ND-70928 (E), Issue 1.0
• Check the site for installing the PBX with the work drawing to verify that
the required floor space is ensured and that service entrances and ducts
for trunk/extension cables, power cables and grounding conductors
have been properly worked at correct positions.
See
Figure 2-7
and
• Detach the SIDE COVER and SIDE PANEL of the Module for 19" RACK
BRACKET (A) mounting. For 19" RACK BRACKET (B), this procedure
is not required. See "Detaching SIDE COVER/SIDE PANEL" on
Page
76.
• Mount the 19" RACK BRACKET (A) to the PIM. See "Connection of 19"
RACK BRACKET (A)" on
• Mount the PIM with the 19" RACK BRACKET (A) to the 19-inch RACK.
See "Mounting PIM to 19-inch RACK" on
• Mount the 19" RACK BRACKET (B) to the bottom-stack PIM. See "Con-
nection of 19" RACK BRACKET (B)" on
• Mount the 19" RACK BRACKET (A) to the top-stack PIM. See "Connec-
tion of 19" RACK BRACKET (A)" on
• Mount the PIMs with the 19" RACK BRACKET (A) and (B) to the 19-inch
RACK. See
Figure
• Carefully review every step above to ensure that all necessary screws
are properly placed and tightened.
Figure
2-8.
Page
78.
Page
2-25.
CHAPTER 2 INSTALLATION
19-inch Rack Mounting Installation
Page
79.
Page
80.
78.
Page 75