NEC NEAX 2000IVS2 Installation Manual page 303

Integrated voice server
Hide thumbs Also See for NEAX 2000IVS2:
Table of Contents

Advertisement

SWITCH
NAME
SW3 (DIP SW)
ON
1 2 3 4
JPS (Jumper pin)
JPR (Jumper pin)
JP (Jumper pin)
The figure in the SWITCH NAME column and the position in
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and
, the setting of the switch varies with the system concerned.
NOTE:
When the power is on, flip the MB switch to ON (UP position) before plugging/unplug-
ging the circuit card.
2
NEAX2000 IVS
Installation Procedure Manual
ND-70928 (E), Issue 1.0
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
SWITCH
SETTING
NUMBER
POSITION
1
ON
2
ON
3
ON
ON
4
OFF
Right
Left
Right
Left
UP
DOWN
FUNCTION
Always set to ON
Always set to ON
Always set to ON
When mounting this card on remote
site.
When mounting this card on main
site.
TA is grounded on the transmission
line: 75 ohms (For coaxial cable)
Balanced transmission: 120 ohms
(For twisted-pair cable)
RA is grounded on the transmission
line: 75 ohms (For coaxial cable)
Balanced transmission: 120 ohms
(For twisted-pair cable)
Line impedance:
75 ohms (For coaxial cable)
Line impedance:
120 ohms (For twisted-pair cable)
in the SETTING POSITION
PN-DAIF (DAI)
CHECK
Page 277