SYSTEM INITIALIZATION
There are two methods for System Initialization. The first method is to Clear All
Data, except LEN000 as a CAT terminal, then program the System Data. The
second method is to use the Resident System Program, which causes the sys-
tem to configure itself automatically to the default settings, wherever the line/
trunk cards are installed.
NOTE 1: See CHAPTER 3 for MP switch settings.
NOTE 2: Refer to the Command Manual for default settings on the Resident System Program.
All Clear, Except LEN000 CAT
STEP 1: Turn on the "SW1" switch on all the PZ-PW121 cards.
- The "ON" lamp must be lit on all the PZ-PW121 cards.
STEP 2: On the MP Card, set SW3 to "B" and press SW1.
STEP 3: When the "MN" lamp on the system is lit, set SW3 to the "0" position and press SW1.
- The operating mode has been changed to the ON LINE mode.
Resident System Program
STEP 1: Mount the line/trunk cards into PIM.
STEP 2: Turn on the "SW1" switch on all the PZ-PW121 cards.
- The "ON" lamp must be lit on all the PZ-PW121 cards.
STEP 3: On the MP card, set SW3 to "C" and press SW1.
- After 30 to 40 seconds, the "MN" lamp turns on.
- The system has loaded the Resident System Program.
NOTE:
If the "MJ" lamp is lit, repeat Step 3.
STEP 4: On the MP card, set SW3 to the "0" position and press SW1.
- The operating mode has been changed to the ON LINE mode.
2
NEAX2000 IVS
Installation Procedure Manual
ND-70928 (E), Issue 1.0
CHAPTER 2 INSTALLATION
Page 209
System Initialization