NEC NEAX 2000IVS2 Installation Manual page 307

Integrated voice server
Hide thumbs Also See for NEAX 2000IVS2:
Table of Contents

Advertisement

SWITCH NAME
SW0
(Piano Key SW)
OFF
8
7
6
5
4
3
2
1
ON
2
NEAX2000 IVS
Installation Procedure Manual
ND-70928 (E), Issue 1.0
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
SWITCH
SETTING
NUMBER
POSITION
ON
1
NOTE 3
NOTE 4
OFF
ON
2
NOTE 3
NOTE 4
OFF
ON
3
OFF
ON
4
OFF
ON
5
OFF
ON
6
OFF
ON
7
OFF
8
OFF
FUNCTION
Source clock signal from network is
sent to the PLO 0 input on MP card.
Source clock signal from network is
not sent to the PLO 0 input on MP
card.
Source clock signal from network is
sent to the PLO 1 input on MP card.
Source clock signal from network is
not sent to the PLO 1 input on MP
card.
Remote loop-back
For normal operation
Local loop-back (AIS send)
For normal operation
Set equalizer according to the cable
length between the PBX and the
MDF.
SW0-5 SW0-6 SW0-7
CABLE LENGTH
ON
ON
ON
0-40m (0-131.2ft.)
ON
ON
OFF
40-80m (131.2-262.5ft.)
ON
OFF
ON
80-120m (262.5-394ft.)
ON
OFF
OFF
120-160m (394-525ft.)
OFF ON
ON
160-200m (525-656ft.)
OFF OFF
OFF
Signal is not sent
Not used
PN-24DTA-C (DTI)
CHECK