NEC NEAX 2000 IVS2 Retrofit Manual
Hide thumbs Also See for NEAX 2000 IVS2:

Advertisement

Quick Links

ND-71075 (E)
ISSUE 1
STOCK # 152015
®
Retrofit System Guide
includes NEAX
1000 IVS
®
JUNE, 2000
NEC America, Inc.

Advertisement

Table of Contents
loading

Summary of Contents for NEC NEAX 2000 IVS2

  • Page 1 ND-71075 (E) ISSUE 1 STOCK # 152015 ® Retrofit System Guide includes NEAX 1000 IVS ® JUNE, 2000 NEC America, Inc.
  • Page 2 NEC America, Inc. reserves the right to change the specifications, functions, or features, at any time, without notice. NEC America, Inc. has prepared this document for use by its employees and customers. The information contained herein is the property of NEC America, Inc. and shall not be reproduced without prior written approval from NEC America, Inc.
  • Page 3 ISSUE No. ISSUE No. PAGE No. PAGE No. ISSUE 1 ISSUE 2 ISSUE 3 ISSUE 4 DATE JUNE, 2000 DATE DATE DATE ISSUE 5 ISSUE 6 ISSUE 7 ISSUE 8 DATE DATE DATE DATE NEAX2000 IVS Revision Sheet 1/1 Retrofit System Guide ND-71075 (E)
  • Page 4: Table Of Contents

    NEAX2000 IVS Retrofit System Guide TABLE OF CONTENTS Page LIST OF FIGURES ............LIST OF TABLES .
  • Page 5: List Of Figures

    LIST OF FIGURES Figure Title Page Figure 2-1 Static Electricity Guard (1 of 2) ......... . Figure 2-1 Static Electricity Guard (2 of 2) .
  • Page 6: List Of Tables

    LIST OF TABLES Table Title Page Table 1-1 Required Hardware/Software ......... . . Table 1-2 System Capacity .
  • Page 7: Introduction

    INTRODUCTION Outline of this Guide INTRODUCTION OUTLINE OF THIS GUIDE This guide explains the system outline and installation procedure of the Retrofit system. The Retrofit system provides the former PBX system users with NEAX2000 IVS equivalent features. This guide contains the following chapters: CHAPTER 1 GENERAL INFORMATION This chapter explains the hardware/software requirements, system capacity, and system...
  • Page 8: Reference Manual

    INTRODUCTION Reference Manual REFERENCE MANUAL During Installation, refer also to the manuals below: NEAX2000 IVS, NEAX7400 ICS Describes the installation procedure of the former Model 110/120, NEAX7400 ICS system. Model 80VS/100 Installation Procedure Manual: NEAX2000 IVS, NEAX7400 ICS Describes the mounting location, the meaning of lamp Model 110/120, NEAX7400 ICS indications, and the method of switch settings of each Model 80VS/100...
  • Page 9: Chapter 1 General Information

    CHAPTER 1 GENERAL INFORMATION This chapter explains the hardware/software requirements, system capacity, and system conditions for the Retrofit system. NEAX2000 IVS Retrofit System Guide Page 3 ND-71075 (E), Issue 1.0...
  • Page 10: Hardware/Software Requirements

    CHAPTER 1 GENERAL INFORMATION Hardware/Software Requirements HARDWARE/SOFTWARE REQUIREMENTS To upgrade the former system, the following hardware and software must be changed. Table 1-1 Required Hardware/Software ITEM FORMER SYSTEM RETROFIT SYSTEM PN-CP00 PN-CP16 (including MP PN-CP00-B program) PN-CP00-C PN-CP03 PN-CP03-C PN-CP07 PN-CP07-C PN-CP01 PN-CP17...
  • Page 11: System Capacity

    CHAPTER 1 GENERAL INFORMATION System Capacity SYSTEM CAPACITY Table 1-2 shows the system capacity of former system and Retrofit system. 48-port PIM: NEAX1000 IVS 64-port PIM: NEAX2000 IVS, NEAX7400 ICS Model 120, NEAX7400 ICS Model 100 72-port PIM: NEAX2000 IVS Small Platform System, NEAX7400 ICS Model 110, NEAX7400 ICS Model 80VS Table 1-2 System Capacity FORMER SYSTEM...
  • Page 12 CHAPTER 1 GENERAL INFORMATION System Capacity Table 1-2 System Capacity FORMER SYSTEM RETROFIT SYSTEM ITEM 48-PORT 64-PORT 72-PORT 48-PORT 64-PORT 72-PORT NOTE 1 NOTE 1 NOTE 1 CS/ZT NOTE 3 Station No. Digits Trunk Access Code Digits Virtual Stations CCIS Routes NOTE 4 NOTE 4 NOTE 4...
  • Page 13 CHAPTER 1 GENERAL INFORMATION System Capacity Table 1-2 System Capacity FORMER SYSTEM RETROFIT SYSTEM ITEM 48-PORT 64-PORT 72-PORT 48-PORT 64-PORT 72-PORT Call Forwarding- Outside Settings NOTE 1 NOTE 1 NOTE 1 MP Built-in 128/32 128/32 128/32 256/64 256/64 256/64 SMDR Memory 1,024/255 1,024/255 1,024/255...
  • Page 14: System Conditions

    CHAPTER 1 GENERAL INFORMATION System Conditions SYSTEM CONDITIONS System Configurations • The PIMs for the NEAX2000 IVS /NEAX7400 ICS M100MX cannot be mounted together with the PIMs for the former system. • The Expanded highway for application processor cards can be used on PIM0 only. •...
  • Page 15: Maintenance Administration Terminal (Mat)

    CHAPTER 1 GENERAL INFORMATION System Conditions Maintenance Administration Terminal (MAT) • MATWorX Studio for the NEAX2000 IVS /NEAX7400 ICS M100MX is required for the Retrofit system. MATWorX 32 for the former system cannot be used for the Retrofit system. • Existing system data for the former system cannot be reloaded for the Retrofit system. New data entry is required when the system is upgraded.
  • Page 16: Chapter 2 Installation

    CHAPTER 2 INSTALLATION This chapter explains the hardware installation procedure, mounting location, the meaning of lamp indications, and the method of switch settings of each circuit card for the Retrofit system. NEAX2000 IVS Retrofit System Guide Page 11 ND-71075 (E), Issue 1.0...
  • Page 17: Precautions

    CHAPTER 2 INSTALLATION Precautions PRECAUTIONS Static Electricity Guard You must wear a grounded wrist strap to protect circuit cards from static electricity. Figure 2-1 Static Electricity Guard (1 of 2) • WHEN PLUGGING/UNPLUGGING A CIRCUIT CARD FRAME GROUND SCREW WRIST STRAP •...
  • Page 18 CHAPTER 2 INSTALLATION Precautions Figure 2-1 Static Electricity Guard (2 of 2) • WHEN MAKING A SWITCH SETTING ON A CIRCUIT CARD CIRCUIT CARD WEAR A WRIST STRAP AND PERFORM THE WORK ON A GROUNDED CONDUCTIVE WORK SURFACE. • WHEN CARRYING A CIRCUIT CARD CONDUCTIVE CIRCUIT POLYETHYLENE...
  • Page 19 CHAPTER 2 INSTALLATION Precautions Caution You must hold the edge of a circuit card when plugging or unplugging the circuit card. If you touch another area, you may be exposed to hazardous voltages. NEVER TOUCH THE COMPONENTS OR SOLDERED SURFACE WITH BARE HANDS. CARD FRONT NEAX2000 IVS Retrofit System Guide Page 14...
  • Page 20: Installation Procedure

    CHAPTER 2 INSTALLATION Installation Procedure INSTALLATION PROCEDURE Install the Retrofit system according to the following procedure. Caution When the operating power is being supplied to MP card, do not plug/unplug the MP card into/ from its mounting slot. (1) Turn the system power off. (2) Unplug the former MP card (PN-CP00/CP03/CP07) from the MP slot.
  • Page 21: Lamp Indications And Switch Settings

    CHAPTER 2 INSTALLATION Lamp Indications and Switch Settings LAMP INDICATIONS AND SWITCH SETTINGS Table 2-1 shows the control cards for the Retrofit system. Table 2-1 List of Retrofit Control Cards EXTRACTION/ INSERTION WITH POWER ON NAME LAMP SWITCH REFERENCE X: ALLOWED (FUNCTIONAL X: PROVIDED X: PROVIDED...
  • Page 22: Pn-Cp16 (Mp)

    CHAPTER 2 INSTALLATION Lamp Indications and Switch Settings PN-CP16 (MP) Locations of Lamps, Switches, and Connectors EXCONN JACK EXCONN: To CONNR connector on PZ-M537 (EXPMEM) Lamp Indications LAMP COLOR FUNCTION NAME Green Flashes at 120 IPM while this card is operating normally. Green Remains lit while receiving clock signals to the PLO.
  • Page 23 CHAPTER 2 INSTALLATION Lamp Indications and Switch Settings Switch Settings Caution When the operating power is being supplied to this circuit card, do not plug/unplug this circuit card into/from its mounting slot. SWITCH SETTING SWITCH NAME FUNCTION CHECK NUMBER POSITION SW3 (Rotary SW) On Line (Call processing is in progress)
  • Page 24 CHAPTER 2 INSTALLATION Lamp Indications and Switch Settings SWITCH SETTING SWITCH NAME FUNCTION CHECK NUMBER POSITION SW1 (Push SW) For initializing CPU A-law (Australia) (Piano Key SW) µ-law (North America) Selection of PLO0 input (Phase Locked Oscillator) • For clock receiver office: SW2-2 SW2-3 FUNCTION 1.5MHz clock...
  • Page 25 CHAPTER 2 INSTALLATION Lamp Indications and Switch Settings SWITCH SETTING SWITCH NAME FUNCTION CHECK NUMBER POSITION SW4 (Dip SW) Not used Not used 1 2 3 4 Selection of PLO1 input (Phase Locked Oscillator) • For clock receiver office: SW4-3 SW4-4 FUNCTION 1.5MHz clock...
  • Page 26 CHAPTER 2 INSTALLATION Lamp Indications and Switch Settings SWITCH SETTING SWITCH NAME FUNCTION CHECK NUMBER POSITION JP0 (Jumper pin) Not used (Memory backup OFF) For normal operation DOWN Front (Memory backup ON) JP1 (Jumper pin) For using internal tone source DOWN For using external tone source Front...
  • Page 27: Pn-Cp17 (Fp)

    CHAPTER 2 INSTALLATION Lamp Indications and Switch Settings PN-CP17 (FP) Locations of Lamps, Switches, and Connectors SENSE Lamp Indications LAMP COLOR FUNCTION NAME Green Flashes at 120 IPM while the circuit card is operating normally. NEAX2000 IVS Retrofit System Guide Page 22 ND-71075 (E), Issue 1.0...
  • Page 28 CHAPTER 2 INSTALLATION Lamp Indications and Switch Settings Switch Settings SWITCH SETTING SWITCH NAME FUNCTION CHECK NUMBER POSITION SENSE For setting FP No. (Rotary SW) For mounting this card in PIM0 For mounting this card in PIM2 For mounting this card in PIM4 For mounting this card in PIM6 NOTE 1 Not used...
  • Page 29: Chapter 3 Len Layout

    CHAPTER 3 LEN LAYOUT This chapter gives a visual layout of each PIM type before and after the installation of the retrofit. NEAX2000 IVS Retrofit System Guide Page 25 ND-71075 (E), Issue 1.0...
  • Page 30: Len Layout For Cp03/Cp00 Pimn-Ua (64-Port Pims)

    CHAPTER 3 LEN LAYOUT LEN Layout for CP03/CP00 PIMN-UA (64-Port PIMS) 0451 0455 0459 0463 0467 0471 0475 0479 0483 0487 0491 0495 0499 0503 0507 0511 0450 0454 0458 0462 0466 0470 0474 0478 0482 0486 0490 0494 0498 0502 0506 0510...
  • Page 31: Len Layout For Cp16 Pimn-Ua (64 Port Pims)

    CHAPTER 3 LEN LAYOUT LEN Layout for CP16 PIMN-UA (64 Port PIMS) PIM 7 LT10 LT11 LT12 LT13 LT14 LT15 PIM 6 LT10 LT11 LT12 LT13 LT14 LT15 PIM5 LT10 LT11 LT12 LT13 LT14 LT15 PIM 4 LT10 LT11 LT12 LT13 LT14 LT15...
  • Page 32: Len Layout For Cp03 Pimq-Ua (72 Port Pim)

    CHAPTER 3 LEN LAYOUT LEN Layout for CP03 PIMQ-UA (72 Port PIM) LTC 0 LTC 1 LTC 2 PIMQ-UA Slot # 0007 0015 0023 0031 0039 0047 0055 0063 0071 0079 0087 Upper 0006 0014 0022 0030 0038 0046 0054 0062 0070 0078...
  • Page 33: Len Layout For Cp03 Pimaba-Ua (2-Pim Neax1000 Ivs)

    CHAPTER 3 LEN LAYOUT LEN Layout for CP03 PIMABA-UA (2-PIM NEAX1000 IVS) NOTE 1 NOTE 2 NOTE 3 PIM 1 0127 0071 0079 0087 0095 0130 0111 0126 0070 0078 0086 0094 0102 0110 0125 0069 0077 0085 0093 0101 0109 BS01 0124...
  • Page 34: Len Layout For Cp16 Pimaba-Ua (2-Pim Neax1000 Ivs)

    CHAPTER 3 LEN LAYOUT LEN Layout for CP16 PIMABA-UA (2-PIM NEAX1000 IVS) NOTE 1 NOTE 2 NOTE 3 PIM 1 Not Used BS01 (LT00) (LT01) (LT02) (LT03) (LT04) (LT05) (LT06) (LT07) (LT08) BS00 PIM 0 (LT00) (LT01) (LT02) (LT03) (LT04) (LT05) (LT06) (LT07)