Figure 4-1. Stacked Air Intake Hoods - Advanced Energy AE 600 User Manual

Table of Contents

Advertisement

Figure 4‑1. Stacked air intake hoods
2. Insert eyebolts through the lifting point holes on each end of one air intake
hood. Secure the eyebolts.
3. Connect a lifting strap securely to each eyebolt.
 Important
4. Lift the air intake hood using the eyebolt as the lifting point.
 Important
As the air intake hood clears the ground, the hood rotates on the eyebolts,
settling into a correctly oriented position for installation. Carefully guide the
hood with your hands, if necessary, to prevent the hood from swinging.
570-1001791-05A
Use a spreader bar to prevent the lifting straps from crushing the air
intake hood.
Lift the air intake hood from the proper hoisting points only. Each hood
weighs 40 pounds.
Advanced Energy® AE 500 Inverter
Hood lifting point
Lifting point with eyebolt
Installing
4‑3