Table 6‑4. Format for Read Holding Register command  (Continued)
CRC MSB
Table 6‑5. Response format for Read Holding Register command
Modbus address
Command number
Number of bytes of data
First register MSB
First register LSB
Second register MSB
Second register LSB
Nth register MSB
Nth register LSB
CRC LSB
CRC MSB
The Write Single Register command is used to write data to a register.
Table 6‑6. Format for Write Single Register command
Modbus address
Command number
First register MSB
First register LSB
Data MSB
Data LSB
CRC LSB
CRC MSB
Table 6‑7. Response format for Write Single Register command
Modbus address
Command number
570-1001791-05A
Command Information
Response Information
Command Information
Response Information
Data Monitoring and Controls
Advanced Energy® AE 500 Inverter
Command Layout
xx
Response Layout
nn
03
n
xx
xx
xx
xx
xx
xx
xx
xx
Command Layout
nn
06
xx
xx
xx
xx
xx
xx
Response Layout
nn
06
6‑17