External cable interfaces are through bottom or side gland plates. The gland plates
must be in place for operation of the inverter. Gland plate locations are included on
the mechanical drawings in the appendix.

ENVIRONMENTAL REQUIREMENTS

The unit may be installed either indoors or outdoors. If the installation of the inverter
is outdoors, all interconnect conduit and fittings must be rated NEMA 4 (same as the
inverter rating) as required by the NEC. For high temperature locations a shade
structure should be placed over the unit in order to reduce thermal stress and extend
the product's life.
Inverter power output will be de-rated for ambient temperatures in excess of 55°C/
131°F.
Table 3‑2. Cooling and heat rejection rate requirements
Requirement
Cooling air flow rate
(maximum)
Heat rejection rate
(maximum)
GROUNDING AND NEUTRAL
REQUIREMENTS

PV Array Frame Grounding

DANGER:
Do not connect the PV negative or positive conductors to the ground bus
bars provided. The PV array is grounded through the integral GFDI.
Connecting the PV array positive or negative conductors to ground at any
other point in the system would defeat the ground fault protection circuit.
3‑4
Rate
3,800 CFM
78,500 BTM/hr
Planning
Description
No external intake or
exhaust air ports are
required in the building if
air flow volume needs are
met.
n/a