Table 8‑3. Drive (DRV) faults
Display
Display Screen Text
Screen Hex
Value
0001
DRIVE A LOW
0002
DRIVE A HIGH
0004
DRIVE B LOW
0008
DRIVE B HIGH
0010
DRIVE C LOW
0020
DRIVE C HIGH
0040
HW OVERCURRENT A
0080
HW OVERCURRENT B
0100
HW OVERCURRENT C
0200
RMS OVERCURRENT A RMS over-current,
0400
RMS OVERCURRENT B RMS over-current,
0800
RMS OVERCURRENT C RMS over-current,
1000
DC OVERVOLTAGE
2000
DC UNDERVOLTAGE
Voltage Faults
The following table lists the voltage faults, including VAC sense, VDC, and power
supply faults.
570-1001791-05A
Description
Drive protection fault,
phase A low
Drive protection fault,
phase B high
Drive protection fault,
phase C low
Drive protection fault,
phase A high
Drive protection fault,
phase B low
Drive protection fault,
phase C high
Peak over-current,
phase A
Peak over-current,
phase B
Peak over-current,
phase C
phase A
phase B
phase C
DC volts over range
DC volts under range
Troubleshooting and Solar Energy Technical Support
Advanced Energy® AE 500 Inverter
Action
Contact Solar Energy
Technical Support
8‑9