Error
code or
Error contents
message
920.26
Fuser warm-up failure
Fuser type = 2
920.27
Fuser warm-up failure
Fuser type = 2
920.28
Fuser warm-up failure
Fuser type = 2
920.29
Fuser warm-up failure
Fuser type = 2
Description/Action
The fuser hot roll took too long
to heat up after transitioning to
new enhanced mode within
standby control only.
The fuser hot roll fell to far
below desired temperature
while in standby control.
The fuser hot roll is too cool
while checking for slope
change in standby.
The fuser hot roll is too cool
when heating to desired
temperature after slope change
within standby control only.
Possible repair actions
1. Turn the machine off/on
and ensure the fuser unit
assembly is properly
installed.
2. Ensure the proper voltage
fuser is installed in the
machine.
3. Replace the fuser unit
assembly if problem
"Fuser unit
remains. Go to
assembly removal" on
page
4-22.
1. Turn the machine off/on
and ensure the fuser unit
assembly is properly
installed.
2. Ensure the proper voltage
fuser is installed in the
machine.
3. Replace the fuser unit
assembly if problem
remains. Go to
"Fuser unit
assembly removal" on
page
4-22.
1. Turn the machine off/on
and ensure the fuser unit
assembly is properly
installed.
2. Ensure the proper voltage
fuser is installed in the
machine.
3. Replace the fuser unit
assembly if problem
remains. Go to
"Fuser unit
assembly removal" on
page
4-22.
1. Turn the machine off/on
and ensure the fuser unit
assembly is properly
installed.
2. Ensure the proper voltage
fuser is installed in the
machine.
3. Replace the fuser unit
assembly if problem
"Fuser unit
remains. Go to
assembly removal" on
page
4-22.
Diagnostic information