PSU fan or blower is inserted
PSU fan or blower is functioning normally
PSU fan or blower is NOT installed
PSU fan status is unknown.
RAID Level Migration
RAID level migration is started
RAID migration is in progress
RAID level migration is completed
RAID level migration is paused
RAID level migration is resumed
RAID level migration is stopped
RAID level migration has encountered a
physical disk error
RAID level migration is aborted due to an
internal error.
RAID level migration is queued
Migration has detected stale NV Watermark
Migration has cleared stale NV Watermark
Array was made incomplete due to missing
NV Watermark
User has accepted Incomplete Array. (Caused
by a missing NV Watermark)
Rebuild
Rebuild is started
Rebuild is in progress
Rebuild is completed
Rebuild is paused
Rebuild is resumed
Rebuild is stopped
Rebuild stopped internally
Rebuild is aborted
Rebuild is queued
Auto rebuild cannot start
Redundancy Check
Redundancy Check is started
Redundancy Check is completed
Redundancy Check is paused
Redundancy Check is resumed
Redundancy Check is stopped
Redundancy Check is aborted due to internal
error
223
No action is required.
Check fans or blowers.
Check for proper installation and turn on the power
supply. If the condition persists, replace the power
supply.
No action is required.
Resume migration when ready.
No action is required.
If this action was not intentional, check the logical
drive's status.
Check the disk drive check table after migration and
replace disk drive as needed.
Reduce system load on the ASUS DS300f G2.
No action is required.
Wait to see if the watermark clears.
No action is required.
If the array is online, try migration again. If the array is
offline, delete and recreate the array.
Rebuild the disk array.
No action is required.
Resume rebuild when ready.
No action is required.
If this action was not intentional, check the logical
drive's status.
Contact Tech Support.
Reduce system load on the ASUS DS300f G2.
No action is required.
Install a target physical drive of adequate capacity.
No action is required.
Resume Redundancy Check when ready.
No action is required.
Reduce system load on the ASUS DS300f G2.
Redundancy Check encountered inconsistent
block(s)
Redundancy Check task is queued
Redundancy check is in progress
Redundancy Check task is stopped internally
Redundancy check is started on
unsynchronized logical drive
Resource
Resource is NOT available
SCSI
SCSI host interface controller settings have
changed
SEP
SEP is found
SEP is NOT found
SEP I2C device access failure
SEP I2C device access recovered from failure
Spare Check
Spare check started on the given spare drive
Spare check completed successfully on the
given spare drive
Spare Drives
Physical disk assigned as global spare
Physical disk is no longer assigned as global
spare
Global Spare has been deleted
Physical disk assigned as dedicated spare
Physical disk is no longer assigned as
dedicated spare
Dedicated Spare has been deleted
SMART
SMART error is received
Stripe Level Migration
Stripe Level migration is started
Stripe Level migration is completed
Stripe Level migration is paused
Stripe Level migration is resumed
Stripe Level migration is stopped
Stripe Level migration has encountered a
physical disk error
Stripe Level migration is aborted due to an
internal error.
Stripe Level migration is queued
Synchronization
Synchronization is started
DS300f G2 Series User Manual
Check the disk drive check table after RC and replace
disk drive as needed.
No action is required.
Restore the disk array to functional status.
No action is required.
Reduce system load on the ASUS DS300f G2.
No action is required.
No action is required.
Insert or replace SEP hardware.
If this message appears repeatedly, contact Tech
Support.
No action is required.
No action is required.
If this message appears repeatedly, replace the physical
drive.
No action is required.
Resume SLM when ready.
No action is required.
If this action was not intentional, check the logical
drive's status.
Check the physical drive check table after OCE is
finished.
Reduce system load on the ASUS DS300f G2.
No action is required.
No action is required.