Making Iscsi Portal Settings; Deleting Iscsi Portals; Viewing A List Of Iscsi Ports; Ortal - Asus DS300j G2 Series User Manual

Disk array subsystems
Table of Contents

Advertisement

To add a portal:
1. Click the Device tab.
2. Click the iSCSI Management icon.
3. Click the Portal tab.
4. Click the Create Portal button.
5. Make your choices and inputs as required:
• Choose an Association type from the option list.
The choices are PHY or Trunk ,
• If you are creating a PHY association, choose
• Controller ID (1 or 2) from the drop-down menu.
• Choose a Port ID (1 to 4) from the drop-down menu.
• If you want to use VLAN, click enable VLAN and fill a VLAN tag from (1 to 4094).
• If you are creating a Trunk association, choose a Trunk ID (1 to 8) from the drop-down menu.
• Type the IP address of the portal in the field provided.
• Type the subnet mask of the portal in the field provided.
• Type the gateway IP address of the portal in the field provided.
• From the IP Type drop-down menu, choose IPv4 or IPv6.
DHCP is currently supported only for IPv4.
6. Click the Submit button.
The new portal is added to the list.
To assign a portal to a target, see "Assigning a Portal to an iSCSI Target"
m
ScSI P
S
akInG I

ortal

ettInGS
To make iSCSI portal settings:
1. Click the Device tab.
2. Click the iSCSI Management icon.
3. Click the Portal tab.
4. Click the portal you want, then click the Settings button.
5. Make settings changes as needed:
• If you have a Trunk association, choose a Trunk ID (1 to 8) from the drop-down menu.
• Type the IP address of the portal in the field provided.
• Type the subnet mask of the portal in the field provided.
• If you have a VLAN association, enter a VLAN tag (1 to 4094) in the field provided.
112
• From the IP Type drop-down menu, choose IPv4 or IPv6.
DHCP is currently supported only for IPv4.
6. Click the Submit button.
D
ScSI P
eletInG I
ortalS
To delete an iSCSI portal:
1. Click the Device tab.
2. Click the iSCSI Management icon.
3. Click the Portal tab.
4. Click the portal you want, then click the Delete button.
5. In the Confirmation box, type the word "
The portal is removed from the list.
v
l
ScSI P
IewInG a
ISt of I
ortS
An iSCSI port is the physical iSCSI connection on the ASUS DS300f G2. There are four iSCSI ports on each RAID
controller for a total of eight per subsystem.
To view a list of ports:
1. Click the Device tab.
2. Click the iSCSI Management icon.
3. Click the Port tab.
Port information includes:
• Port ID – ID number of the port
• Controller ID – 1 or 2
• Link Status – Up or down, active or Inactive
• Jumbo Frames – Enabled or disabled*
• Current Speed – In Mb/s
• Assigned Portals – Portals to which this port is assigned
Items marked with an asterisk (*) are adjustable under "Making iSCSI Port Settings"
DS300f G2 Series User Manual
" in the field provided and click the Confirm button.
confirm