There are two methods for shutting down the subsystem. Choose one of the following procedures:
• "Shutting down the ASUS DS300f G2 – Telnet Connection" on page 168
• "Shutting down the ASUS DS300f G2 – Serial Connection" on page 168
S
aSuS DS300
huttInG Down the
f
This function shuts down the ASUS DS300f G2 subsystem on a Telnet connection. Additional action is required,
as described below.
Important
If you have a JBOD Expansion, always power off the RAID subsystem first. Then power
off the JBOD subsystems.
To shutdown the RAID subsystem:
1. From the Main Menu, highlight Additional Info and Management and press Enter .
2. Highlight Shutdown or Restart and press Enter .
3. Highlight Option and press the spacebar to display Shutdown .
4. Highlight Submit and press Enter .
A warning message appears.
5. Press Y to continue.
The screen goes blank.
6. Wait for no less than two minutes.
7. The subsystem will then turn off the system power one after another.
168
(Clu)
ubsysteM
G2 – t
c
elnet
onnectIon
S
aSuS DS300
huttInG Down the
f
This function shuts down the ASUS DS300f G2 subsystem on a SSH connection. Additional action is required,
as described below.
Important
If you have a JBOD Expansion, always power off the RAID subsystem first. Then power off the
JBOD subsystems.
To shutdown the RAID subsystem:
1. From the Main Menu, highlight Additional Info and Management and press Enter .
2. Highlight Shutdown or Restart and press Enter .
3. Highlight Option and press the spacebar to display Shutdown .
4. Highlight Submit and press Enter .
A warning message appears.
5. Press Y to continue.
6. Close your SSH session.
7. Wait for no less than two minutes.
8. The subsystem will then turn off the system power one after another.
S
aSuS DS300
huttInG Down the
f
This function shuts down the ASUS DS300f G2 subsystem on a serial connection. Additional action is required,
as described below.
Important
If you have a JBOD Expansion, always power off the RAID subsystem first. Then power off
the JBOD subsystems.
To shutdown the RAID subsystem:
1. From the Main Menu, highlight Additional Info and Management and press Enter .
2. Highlight Shutdown or Restart and press Enter .
3. Highlight Shutdown or Restart and press Enter .
4. Highlight Option and press the spacebar to display Shutdown .
DS300f G2 Series User Manual
G2 – SSh c
onnectIon
G2 – S
c
erIal
onnectIon

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds300f g2 seriesDs300 g2 series

Table of Contents