RAID 5
3 physical drives minimum, 32 maximum.
RAID 0 must have less than 16 physical drives.
If existing physical drives have no unused space, add 1 or more physical
drives.
RAID 6
4 physical drives minimum, 32 maximum.
If existing physical drives have no unused space, add 1 or more physical
drives.
RAID 10
4 physical drives minimum.
Even number of physical drives.
If existing physical drives have no unused space, add 1 or more physical
drives.
RAID 50
6 physical drives minimum, 32 per axle maximum.
If existing physical drives have no unused space, add 1 or more physical
drives.
RAID 60
8 physical drives minimum, 32 per axle maximum.
If existing physical drives have no unused space, add 1 or more physical
drives.
rAid 1
A RAID 1 Source logical drive can migrate to the following Target logical drives:
Target
Requirements
RAID 0
None.
RAID 1E
3 or more physical drives.
Add 1 or more physical drives.
RAID 5
3 physical drives minimum, 32 maximum.
RAID 1 must have less than 32 physical drives.
Add 1 or more physical drives.
RAID 10
4 physical drives minimum.
Even number of physical drives.
Add 2 or more physical drives.
RAID 50
6 physical drives minimum, 32 per axle maximum.
Add 4 or more physical drives.
rAid 1e
A RAID 1E Source logical drive can migrate to the following Target logical drives:
Target
Requirements
RAID 0
None.
RAID 1E
Add physical drives.
RAID 5
3 physical drives minimum, 32 maximum.
RAID 1E must have less than 32 physical drives.
If existing physical drives have no unused space, add 1 or more physical drives.
190
RAID 10
4 physical drives minimum.
Even number of physical drives.
If existing physical drives have no unused space, add 1 or more physical drives.
RAID 50
6 physical drives minimum, 32 per axle maximum.
rAid 3
A RAID 3 Source logical drive can migrate to the following Target logical drives:
Target
Requirements
RAID 0
None.
RAID 1E
None
RAID 3
Add physical drives. 32 maximum.
RAID 5
3 physical drives minimum. 32 maximum. If existing physical drives have no
unused space add 1 or more physical drives..
RAID 6
4 physical drives minimum, 32 maximum.
If existing physical drives have no unused space, add 1 or more physical
drives.
RAID 10
4 physical drives minimum.
Even number of physical drives.
If existing physical drives have no unused space, add 1 or more physical
drives.
RAID 30, 50
6 physical drives minimum, 32 per axle maximum.
If existing physical drives have no unused space, add 1 or more physical
drives.
RAID 60
8 physical drives minimum, 32 per axle maximum.
If existing physical drives have no unused space, add 1 or more physical
drives.
rAid 5
A RAID 5 Source logical drive can migrate to the following Target logical drives:
Target
Requirements
RAID 0
None.
RAID 1E
None.
RAID 5
Add physical drives. 32 maximum.
RAID 6
4 physical drives minimum, 32 maximum.
If existing physical drives have no unused space, add 1 or more physical
drives.
RAID 10
4 physical drives minimum.
Even number of physical drives.
If existing physical drives have no unused space, add 1 or more physical
drives.
RAID 50
6 physical drives minimum, 32 per axle maximum.
If existing physical drives have no unused space, add 1 or more physical
drives.