6. Type the recipient's IP address into the field provided.
7. Highlight Message Event Severity Filter and press the spacebar to change severity levels.
The selected level and all higher severity levels of severity are reported.
See the Table below.
8. Press Control-A to save your settings.
Event Severity Levels
Level
Description
Fatal Non-recoverable error or failure has occurred.
Critical Action is needed now and the implications of the condition are serious.
Major Action is needed now.
Minor Action is needed but the condition is not a serious at this time.
Warning User can decide whether or not action is required.
Information Information only, no action is required.
d
n
r
eleting
etsend
eciPients
To delete a Netsend recipient:
1. From the Main Menu, highlight Additional Info and Management and press Enter .
2. Highlight Software Management and press Enter .
3. Highlight Netsend and press Enter .
4. Highlight Message Recipients and press Enter .
5. Highlight the recipient you want to delete and press the spacebar to mark it.
The mark is an asterisk (*) to the left of the listing
6. Highlight Delete Marked Entries and press Enter .
f
tftP
laShInG throuGh
Use this function to flash (update) the firmware on the ASUS DS300f G2. See "Updating with the CLU" on page
<OV>
166
v
f
I
IewInG
lash
MaGe
Flash image information refers to the package of firmware components running on your ASUS DS300f G2
controller or controllers.
To view flash image information:
1. From the Main Menu, highlight Additional Info and Management , and press Enter .
2. Highlight Flash Image Version Info and press Enter .
The flash image information displays on the screen:
• Enclosure Number – 1 (one) is the Head Unit. Other numbers are cascaded or expanded subsystems
• Running Image Info – Firmware currently running on the controllers
• Flashed Image Info – Firmware flashed to memory
• Image Type – A specific component
• Controller ID – 1 or 2
• Version number
• Build date
• Flash (installation) date
If the Running and Flashed Images do not match, the ASUS DS300f G2 has not restarted since the
firmware was last updated. Restart the ASUS DS300f G2 to run the Flashed firmware package. See
"Restarting a Subsystem" on page <?>
Note that all of these components are upgraded together in a package. See "Updating with the CLU" on
page <OV>.