on page 135. After rebuilding, the drive shows Stale. Run Clear Stale then run Clear PFA.
If the physical drive with a PFA error is a spare, you must delete the drive as a spare, then Clear PFA is
available.
After you clear a PFA error, watch for another PFA error to appear. If it does, replace the physical drive.
f
P
D
o
(clu)
orcInG a
hySIcal
rIve
fflIne
This function enables you to force an online physical drive to go Offline.
The Force Offline function appears only for physical drives that are assigned to disk arrays.
Caution
Forcing a physical drive offline is likely to cause data loss. Back up your data before
you proceed. Use this function only when required.
Important
Forcing a physical drive offline causes your logical drives to become degraded. If Auto
Rebuild is enabled and a spare drive is available, the disk array begins rebuilding itself
automatically.
To force a physical drive offline:
1. From the Main Menu, highlight Physical Drive Management and press Enter .
2. Highlight Global Physical Drives Settings and press Enter .
3. Highlight the physical drive you want and press Enter .
4. Highlight Force Offline and press Enter .
5. Press Y to confirm.
131
l
P
D
(clu)
ocatInG a
hySIcal
rIve
This feature helps you identify a physical drive within the ASUS DS300f G2 enclosure you are working with
through the CLU. To locate a physical drive:
1. From the Main Menu, highlight Physical Drive Management and press Enter .
2. Highlight Global Physical Drives Settings and press Enter .
3. Highlight the physical drive you want and press Enter .
4. Highlight Locate Physical Drive and press Enter .
The drive carrier status LED flashes for one minute.
Figure 5 - 5: Drive carrier status LED
DS300f G2 Series User Manual
Drive Status LED
Power/Activity LED