Managing The Enclosure (Clu) - Asus DS300j G2 Series User Manual

Disk array subsystems
Table of Contents

Advertisement

M
e
anaGInG the
nClosure
Enclosure Management includes the following functions:
• "Viewing the Enclosures Summary (CLU)" on page 126
• "Viewing Enclosure Information (CLU)" on page 126
• "Making Enclosur e Settings (CLU)" on page 126
• "Viewing Power Supply Status (CLU)" on page 127
• "Locating a Power Supply (CLU)" on page 127
• "Viewing Cooling Unit Status (CLU)" on page 127
• "Viewing Temperature Sensor Status (CLU)" on page 127
• "Viewing Voltage Sensor Status (CLU)" on page 127
• "Viewing Battery Information (CLU)" on page 128
• "Locating an Enclosure (CLU)" on page 128
v
e
S
(clu)
IewInG the
ncloSureS
ummary
Enclosure Management includes information, status, settings and location. To access Enclosure Management:
1. From the Main Menu, highlight Subsystem Management and press Enter .
2. Highlight Enclosure Management and press Enter .
The following information is shown:
• Enclosure ID number
• Enclosure Type
• Operational Status
• Status Description (specific components in need of attention, if any)
126
(Clu)
v
e
I
(clu)
IewInG
ncloSure
nformatIon
To view enclosure information:
1. From the Main Menu, highlight Subsystem Management and press Enter .
2. Highlight Enclosure Management and press Enter .
3. Highlight the enclosure you want and press Enter .
You can monitor power supplies, cooling units, enclosure temperatures and voltages, and the battery.
A
dJustAble iteMs
You can set or adjust the following items:
• Enclosure Warning and Critical temperature thresholds
• Controller Warning and Critical temperature thresholds
See "Making Enclosure Settings" below.
For information on Enclosure problems, see "Enclosure Problems" on page <?>.
m
e
S
(clu)
akInG
ncloSur e
ettInGS
To make Enclosure settings:
1. From the Main Menu, highlight Subsystem Management and press Enter .
2. Highlight Enclosure Management and press Enter .
3. Highlight the enclosure you want and press Enter .
4. Highlight Enclosure Settings and press Enter .
5. Highlight the Temperature Warning threshold you want to change.
6. Press the backspace key to erase the current value.
7. Type a new interval value in degrees C.
8. Press Control-A to save your settings.