Asus DS300j G2 Series User Manual page 153

Disk array subsystems
Table of Contents

Advertisement

v
ScSI t
I
IewInG I
arGet
nformatIon
To view information for an iSCSI target:
1. From the Main Menu, highlight iSCSI Managemen t and press Enter .
2. Highlight iSCSI Targets and press Enter .
The list of iSCSI Targets displays.
3. Highlight the target you want to change and press Enter .
The target information screen displays. Information includes:
• TargetName – iSCSI qualified name (iqn) of this target.
• TargetAlias – Maximum of 32 characters. Use letters, numbers, space
between words, and underscore. An alias is optional.*
• TargetStatus – Up or down.
• ErrorRecovLevel – Error recovery level supported.
• ImmediateData – Enables the initiator to send unsolicited data with the iSCSI command PDU.
• MaxConnection – Maximum number of connections.
• DataPDUInOrder – Enables placement of data in PDU order.
• InitialR2T – Allows initiator to begin sending data to a target
without receiving a ready to transfer command.
• DataSeqInOrder – Enables placement of data in sequential order.
• OutStandingR2T – Maximum number of R2T PDUs the target
can have outstanding for a single iSCSI command.
• MaxBurstLen – Maximum length of a solicited data sequence in bytes.
• DefTimeToWait – After a dropped connection, the number of
seconds to wait before attempting to reconnect.
• DefTimeToRetain – Number of seconds after time to wait (above)
before reassigning outstanding commands.
• HeaderDigest – Enables the use of header digest (CRC). Enabled or disabled.*
• DataDigest – Enables the use of a data digest (CRC). Enabled or disabled.*
• UniCHAPAuthen – Uni-directional (peer) CHAP authentication, enabled or disabled.*
• BiCHAPAuthen – Bi-directional (local) CHAP authentication, enabled or disabled.*
• FirstBurstLen – First burst length in bytes.
• AssignedPortals – Portals assigned to this target.
• NOP-In: Check iSCSI connection status*
Items marked with an asterisk (*) are adjustable under "Making iSCSI Target Settings (CLU)" on page
<OV>.
147
(clu)
m
ScSI t
S
(clu)
akInG I
arGet
ettInGS
To make target settings:
1. From the Main Menu, highlight iSCSI Managemen t and press Enter .
2. Highlight iSCSI Targets and press Enter .
The list of iSCSI Targets displays.
3. Highlight the target you want to change and press Enter .
The target information screen displays.
4. Highlight iSCSI Target Settings and press Enter .
5. Make new settings as needed.
• Optional. Highlight TargetAlias and type an alias into the field provided.
• Highlight each item and press the Spacebar to toggle between Enable and Disable.
• HeaderDigest – Adds a header digest (CRC).
• DataDigest – Adds a data digest (CRC).
• UniCHAPAuthen – Enables uni-directional CHAP authentication.
• BiCHAPAuthen – Enables bi-directional CHAP authentication.
Authentication requires a pre-existing CHAP.
• Enable NOP-In - Enable to check iSCSI connection status
6. Highlight Save Settings and press Enter .
7. Press Return to Previous Menu to return to the iSCSI targets list.