ADTRAN ATLAS 800 SERIES System Manual page 359

Atlas 800 series
Hide thumbs Also See for ATLAS 800 SERIES:
Table of Contents

Advertisement

ATLAS 800 Series System Manual
System Event Log
3.
SYSTEM EVENTS
Table 1 through Table 8 provide listings of ATLAS system events, including tables of events for each
category, according to the order they appear in the E
Console Log String
AC Power Supply has Recovered
AC Power Supply has Failed
AC Power Supply has Exceeded
Temperature Limit
AC Power Supply is Under Temperature
Limit
DC Power Supply has Recovered
DC Power Supply has Failed
DC Power Supply has Exceeded
Temperature Limit
DC Power Supply is Under Temperature
Limit
Firmware invalid
Firmware update failed
System Configuration Uploaded
Module Not Responding
ACO Switch pressed
Login Failure
Timing source changed to Internal
Timing source changed to Backup
Timing source changed to Primary
Not responding to programming
Cold
Firmware update completed
Module Found
SNMP Authentication Failure
1
Three consecutive logins were attempted and failed.
2
Generated five seconds after the completion of system initialization.
3
Generated if the ATLAS receives an SNMP request from an SNMP manager defined in the ATLAS SNMP communities
list but with a community name that does not match the community name defined in the SNMP communities list.
61200780L1-1C
VENT
Table 1. System Controller Events
Category
CRITICAL
CRITICAL
CRITICAL
CRITICAL
CRITICAL
CRITICAL
CRITICAL
CRITICAL
CRITICAL
CRITICAL
CRITICAL
WARNING
MINOR
MINOR
MINOR
MINOR
MINOR
MINOR
NORMAL
INFO
INFO
INFO
© 2004 ADTRAN, Inc.
L
setup screen.
OG
Event
AC power supply is functioning normal again
AC power supply is not operating properly
Internal system temperature has exceeded
safe operating limit
Internal temperature has cooled to safe
operating limit
DC power supply is functioning normally
again
DC power supply is not operating properly
Internal system temperature has exceeded
safe operating limit
Internal temperature has cooled to safe
operating limit
Corrupted firmware
Flash download failed
ATLAS configuration file loaded into the
system and activated
Module removed or not responding
ACO switch pressed
Console login failure
Neither the primary nor the backup are valid
The primary source is invalid; backup
source valid and selected.
The timing source changed to primary
Unable to program module
2
System cold start
Flash download successful
Module found
SNMP authentication failure