ADTRAN ATLAS 800 SERIES System Manual page 132

Atlas 800 series
Hide thumbs Also See for ATLAS 800 SERIES:
Table of Contents

Advertisement

ATLAS 800 Series System Manual
Options
No Loopback
Local Loopback
Remote Loopback
Loopback Status
511
511 Result
Results
None
LOS
Sync
ES
Inject
CLR
61200780L1-1C
Description
No active loopback.
Activates both a local loopback (back toward the DTE) and a port loopback
(toward the network).
V.54 loopback code to be sent to the far end, and if the device at the far end
supports V.54, the device activates a loopback on detection of the V.54 code.
Read security: 5
This read-only option indicates a port's current loopback status by displaying
any of the following status messages:
No Loopback Active
Looping Up Remote Unit
Remote Unit Looped Back
Looping Down Remote Unit
Remote Loop-Up Failed
Port Looped From Remote Source
Port Loopback Active
Write security: 4; Read security: 5
Controls the activation of the 511 test pattern generator and detector.
Read security: 5
Displays the results of the 511 test. This option is read-only. Clear these results
by pressing <Enter > when
Description
Pattern is not synchronized.
At one point the pattern was synchronized, but is currently not synchronized.
Pattern is synchronized.
Number of seconds with at least one bit error.
Write security: 4; Read security: 4
Injects errors into transmitted test pattern.
Write security: 4; Read security: 4
Clears error counters on test pattern results menu.
© 2004 ADTRAN, Inc.
CLR
is selected.
USSI Option Module
Test
132