ATLAS 800 Series System Manual
Submenus
Sublink -
Frame Relay
(continued)
61200780L1-1C
Description (Continued)
Results [MN/AV/MX Dly]
Displays the minimum, average, and maximum delay for the
delay-measurement test. To display the additional test results,
place the cursor over this field and press <Enter> on the
keyboard. The displayed times are in milliseconds.
Echo Pkt Tx
Displays the total number of test packets that have been
transmitted.
Echo Pkt Rx
Displays the total number of test packets that have been
received.
Echo Pkt Dropped
Displays the total number of packets lost in the receiving
direction (traveling from the remote ADTRAN Frame Relay
device to the ATLAS).
Rmt Pkt Dropped
Displays the total number of packets lost in the transmit
direction (traveling from the ATLAS to the remote ADTRAN
Frame Relay device).
Min Delay
Displays the minimum round trip delay for the current test
period.
Max Delay
Displays the maximum round trip delay for the current test
period.
Avg Delay
Displays the average round trip delay for the current test.
Reset Counters
Resets the counters.
© 2004 ADTRAN, Inc.
Packet Manager
Packet Endpnts
233