Monitoring Functions; General; Diagnostics Display On The Crt - Siemens Sinumerik 810T User Manual

Basic version 3, software version 3
Table of Contents

Advertisement

09.91
4

Monitoring Functions

4.1

General

The control contains permanently active monitoring functions which detect faults in the NC, the
interface control and the machine at such an early stage that damage to the workpiece, tool or
machine are practically eliminated. If a fault occurs, first of all machining is interrupted and the
drives brought to a standstill, and then the reason for the fault is stored and displayed as an
alarm. At the same time the PLC is informed that an NC alarm is present.
Monitoring functions exist for the following areas:
Reading in
Format
Measuring circuit cables
Encoders and drives
Contour
Spindle speed
Enable signals
Voltage
Microprocessors
Serial interfaces
Transfer between NC and PLC
Voltage level of the back-up battery
System program memory
User program memory
4.2

Diagnostics display on the CRT

Messages from the monitoring system are displayed in the "Alarm line" of the CRT display.
The "Alarm line" is the second display line from the top.
Upper CRT display limit
Area for the
alarm no.
and further
ALARM LINE
identifiers
© Siemens AG 1990 All Rights Reserved
SINUMERIK 810T, GA3 (BN)
Area for the
alarm text
6ZB5 410-0EP02
4 Monitoring Functions
4.1 General
4-1