09.91
2078
Alarm No.
Alarm Text:
"Incorrect input parameter"
Reason:
– Programmed parameter sequence not allowed
– Parameter sequence not complete for the described contour
Effect:
As for alarm 2072
Remedy:
As for alarm 2072
2081
Alarm No.
Alarm Text:
"CRC not allowed"
Reason:
With TNRC/CRC selected (G41/G42), the following functions cannot
be programmed:
G33, G34, G35; G58; G59, G92, M19 S ...
Remedy:
First program cancellation of TNRC/CRC
with G40 or D0
2082
Alarm No.
Alarm Text:
"CRC plane not determinable"
Reason:
The axes for the selected CRC/TNRC plane do not exist
Remedy:
Select correct plane with G16
2087
Alarm No.
Alarm Text:
"Coordinate rotation not allowed"
Remedy:
Check NC program
2088
Alarm No.
Alarm Text
"Battery alarm abs. submod. 1"
Reason:
Battery voltage is too low. Battery test is performed every 10 min.
Remedy:
Replace battery module on absolute encoder module 1 while the
control is switched on.
2089
Alarm No.
Alarm Text
"Battery alarm abs. submod. 2"
Reason:
Battery voltage is too low. Battery test is performed every 10 min.
Remedy:
Replace battery module on absolute encoder module 2 while the
control is switched on.
2152
Alarm No.
Alarm Text:
"Spindle speed too high"
Reason:
The actual spindle speed is higher than that set in machine data.
– Program a smaller S value
– G92 S ... with v constant
– Search for a block number in the "EDIT" mode ("AUTOMATIC"
mode)
Remedy:
Check or inform Service
© Siemens AG 1990 All Rights Reserved
SINUMERIK 810T, GA3 (BN)
6ZB5 410-0EP02
4 Monitoring Functions
4.6 Listing of the alarms/alarm description